1.1This specification2 establishes the requirements for seamless tube and ferrule stock of copper and various copper alloys up to 31/8in. [80 mm] inclusive, in diameter, for use in surface condensers, evaporators, and heat exchangers. The following coppers and copper alloys are specified:3
Copper or Copper Alloy UNS No.
Previously Used Designation
Description
C10100
OFE
Oxygen-free electronic
C10200
OFA
Oxygen-free without residual deoxidants
C10300
. . .
Oxygen-free, extra low phosphorus
C10800
Oxygen-free, low phosphorus
C12000
DLPA
Phosphorized, low residual phosphorus
C12200
DHPA
Phosphorized, high residual phosphorus
C14200
DPAA
Phosphorized, arsenical
C19200
Phosphorized, 1 % iron
C23000
Red Brass
C28000
Muntz Metal
C44300
Admiralty Metals, B, C, and D
C44400
C44500
C60800
Aluminum Bronze
C61300
C61400
Aluminum Bronze, D
C68700
Aluminum Brass, B
C70400
95-5 Copper-Nickel
C70600
90-10 Copper-Nickel
C70620
90-10 Copper-Nickel-Welding Grade
C71000
80-20 Copper-Nickel
C71500
70-30 Copper-Nickel
C71520
70-30 Copper-Nickel-Welding Grade
C71640
Copper-nickel-iron-manganese
C72200
1.2Units-The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3The following safety hazards caveat pertains only to the test methods portion, Section 19, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning-Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Safety Data Sheet (SDS) for additional information. Users should be aware that selling mercury and/or mercury containing products in your state or country may be prohibited by law.)
1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.