• AWWA ACE69065

AWWA ACE69065

Pilot Study on TOC Removal in Drinking Water Using Enhanced Coagulation Assisted by Membrane Ultrafiltration

American Water Works Association , 11/01/2008

Publisher: AWWA

File Format: PDF

$12.00$24.00


The U.S. Environmental Protection Agency (USEPA) regulation has been more and more stringent on disinfection byproducts in drinking water distribution systems since the promulgation of the Stage 1 and Stage 2 Disinfection Byproducts Rules. In the past, at the City of Ft. Lupton, Colorado, total trihalomethanes (TTHM) concentrations in the water distribution system exceeded the maximum contamination level (MCL). Currently, a direct membrane microfiltration process followed by chlorine disinfection is employed at the Ft. Lupton Water Treatment Plant, which has been ineffective in the removal of total organic carbon (TOC) (the precursor of disinfection byproducts). Enhanced coagulation assisted by the membrane ultrafiltration eliminates the need for clarification, which significantly reduces the footprint of the plant. Ultrafiltration is also effective in the removal of pathogens, bacteria, and viruses. A pilot study was conducted, the objectives of which were to evaluate the efficiency and feasibility of enhanced coagulation, membrane ultrafiltration, granular activated carbon (GAC), and their combinations on TOC removal and examined the likelihood of the compliance with Stage 2 Disinfection Byproducts Rule (S2DBPR). A pilot plant at the capacity of 4.5 m3/h was set up and run for over two months. Coagulation with ferric sulfate was optimized in terms of pH and chemical dosing rate. Results show that enhanced coagulation assisted by membrane ultrafiltration achieved up to 56% TOC removal at pH 5.7 and 25 mg/L ferric dose. The membrane flux was stable at 1.5 L/m2/min for about 1 month without the need for chemical cleaning for recovery. Appending GAC columns to direct membrane ultrafiltration achieved 45% TOC removal for GAC20 and 17% TOC removal for GAC10. About 80% of TOC was removed with the combination of enhanced coagulation, membrane ultrafiltration, and GAC10 filtration. Simulated Distribution System (SDS)-TTHM analysis indicated that enhanced coagulation and GAC20 will lead to S2DBPR compliance if implemented individually. Opinions of Probable Costs (OPC) for different combinations were estimated and indicated that enhanced coagulation assisted by membrane ultrafiltration was cost effective. Includes 8 references, tables, figures.

More AWWA Standards PDF

AWWA WQTC52866

AWWA WQTC52866

$12.00 $24.00

AWWA WQTC52748

AWWA WQTC52748

$12.00 $24.00

AWWA 51539

AWWA 51539

$12.00 $24.00

Pocket Ref

Pocket Ref

$11.00 $22.00