• ISA 60079-29-1

ISA 60079-29-1

Explosive Atmospheres – Part 29-1: Gas detectors – Performance requirements of detectors for flammable gases

The International Society of Automation , 06/26/2013

Publisher: ISA

File Format: PDF

$252.00$505.00


W/D S/S BY UL 60079-29-1

This part of ANSI/ISA-60079-29 specifies general requirements for construction, testing and performance, and describes the test methods that apply to portable, transportable and fixed apparatus for the detection and measurement of flammable gas or vapour concentrations with air. The apparatus, or parts thereof, are intended for use in potentially explosive gas atmospheres (see 3.1.3) and in mines susceptible to firedamp.

This standard is applicable to flammable gas detection apparatus intended to provide an indication, alarm or other output function; the purpose of which is to give a warning of a potential explosion hazard and in some cases, to initiate automatic or manual protective action(s).

This standard is applicable to apparatus, including the integral sampling systems of aspirated apparatus, intended to be used for commercial, industrial and non-residential safety applications.

This standard does not apply to external sampling systems, or to apparatus of laboratory or scientific type, or to apparatus used only for process control purposes. It also does not apply to open path (line of sight) area monitors. For apparatus used for sensing the presence of multiple gases, this standard applies only to the detection of flammable gas or vapour.

This standard supplements and modifies the general requirements for the type of protection covered in appropriate ANSI standards of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of the type of protection covered in appropriate ANSI standards , the requirement of ANSI/ISA-60079-29-1 will take precedence.

NOTE 1 ANSI/ISA-60079-29-1 is intended to provide for the supply of apparatus giving a level of safety and performance suitable for general purpose applications. However, for specific applications, a prospective purchaser (or an appropriate authority) may additionally require the apparatus to be submitted to particular tests or approval. For example, Group I apparatus (i.e. apparatus to be used in mines susceptible to firedamp) may not be permitted to be used without the additional, prior approval of the relevant authority in mines under its jurisdiction. Such particular tests/approval are to be regarded as additional to and separate from the provisions of the standards referred to above and do not preclude certification to or compliance with these standards.

NOTE 2 All apparatus calibrated on specific gases or vapours can not be expected to correctly indicate on other gases or vapours.

NOTE 3 For the purposes of this standard, the terms "lower flammable limit (LFL)" and "lower explosive limit (LEL)" are deemed to be synonymous, and likewise the terms "upper flammable limit (UFL)" and "upper explosive limit (UEL)" are deemed to be synonymous. For ease of reference, the two abbreviations LFL and UFL may be used hereinafter to denote these two sets of terms. It should be recognized that particular authorities having jurisdiction may have overriding requirements that dictate the use of one of these sets of terms and not the other.

NOTE 4 For the purposes of this standard, the term "indicating up to a volume fraction of X %" includes apparatus with an upper limit of the measuring range equal to or less than X %.